Connecting switches between two buildings, each building has it own mains electrical supply












14














I have two buildings (A + B) each with their own mains electrical supply. The buildings are about 20m from one another. Between the two buildings are the Cat6 cables (one active and two spares).



The Cat6 cable is terminated in a patching / data rack in each building.



Both buildings have their own patch panel and network switch. Building A houses the modem and router.



My concern is that I've heard having connected electrical devices / equipment, across two or more mains electrical supplies can cause issues / damage to the electrical devices / equipment due to different mains electrical supplies having different grounds / earths.



Is this a valid concern? And what can I do to rectify the issue?










share|improve this question
























  • If the supplies are properly earthed there should be no issue. In any case, Ethernet cables do not normally carry power, unless you are running PoE, which I don't think you will be.
    – DavidPostill
    Dec 9 '18 at 20:37
















14














I have two buildings (A + B) each with their own mains electrical supply. The buildings are about 20m from one another. Between the two buildings are the Cat6 cables (one active and two spares).



The Cat6 cable is terminated in a patching / data rack in each building.



Both buildings have their own patch panel and network switch. Building A houses the modem and router.



My concern is that I've heard having connected electrical devices / equipment, across two or more mains electrical supplies can cause issues / damage to the electrical devices / equipment due to different mains electrical supplies having different grounds / earths.



Is this a valid concern? And what can I do to rectify the issue?










share|improve this question
























  • If the supplies are properly earthed there should be no issue. In any case, Ethernet cables do not normally carry power, unless you are running PoE, which I don't think you will be.
    – DavidPostill
    Dec 9 '18 at 20:37














14












14








14


2





I have two buildings (A + B) each with their own mains electrical supply. The buildings are about 20m from one another. Between the two buildings are the Cat6 cables (one active and two spares).



The Cat6 cable is terminated in a patching / data rack in each building.



Both buildings have their own patch panel and network switch. Building A houses the modem and router.



My concern is that I've heard having connected electrical devices / equipment, across two or more mains electrical supplies can cause issues / damage to the electrical devices / equipment due to different mains electrical supplies having different grounds / earths.



Is this a valid concern? And what can I do to rectify the issue?










share|improve this question















I have two buildings (A + B) each with their own mains electrical supply. The buildings are about 20m from one another. Between the two buildings are the Cat6 cables (one active and two spares).



The Cat6 cable is terminated in a patching / data rack in each building.



Both buildings have their own patch panel and network switch. Building A houses the modem and router.



My concern is that I've heard having connected electrical devices / equipment, across two or more mains electrical supplies can cause issues / damage to the electrical devices / equipment due to different mains electrical supplies having different grounds / earths.



Is this a valid concern? And what can I do to rectify the issue?







networking power-supply






share|improve this question















share|improve this question













share|improve this question




share|improve this question








edited Dec 9 '18 at 20:48









Twisty Impersonator

17.7k146395




17.7k146395










asked Dec 9 '18 at 20:34









sam

1,506133569




1,506133569












  • If the supplies are properly earthed there should be no issue. In any case, Ethernet cables do not normally carry power, unless you are running PoE, which I don't think you will be.
    – DavidPostill
    Dec 9 '18 at 20:37


















  • If the supplies are properly earthed there should be no issue. In any case, Ethernet cables do not normally carry power, unless you are running PoE, which I don't think you will be.
    – DavidPostill
    Dec 9 '18 at 20:37
















If the supplies are properly earthed there should be no issue. In any case, Ethernet cables do not normally carry power, unless you are running PoE, which I don't think you will be.
– DavidPostill
Dec 9 '18 at 20:37




If the supplies are properly earthed there should be no issue. In any case, Ethernet cables do not normally carry power, unless you are running PoE, which I don't think you will be.
– DavidPostill
Dec 9 '18 at 20:37










2 Answers
2






active

oldest

votes


















18














It won't be a problem. The Ethernet standards for twisted-pair have always required isolation of the signal wires from all local power supplies and grounds. In most equipment using twisted-pair Ethernet this is achieved simply by having all of the pairs run through transformers at each end. There is therefore no metallic connection between the switches or whatever the TP cable is plugged into, and therefore complete isolation, between the equipments' grounds and power supplies.



If you were using shielded twisted pair, you would want to connect its shield to building frame ground at one and only one end. This was a concern back in the days of 10Base2 and 10Base5 (Ethernet over coax).






share|improve this answer



















  • 5




    So what about PoE?
    – DavidPostill
    Dec 9 '18 at 21:20






  • 3




    Ethernet uses differential signalling. Thus the interface looks at difference between two wires, not absolute voltage levels. No common zero needs to be identified, as the difference will be equal no matter what gnd is with reference to the other end.
    – vidarlo
    Dec 9 '18 at 21:21






  • 3




    PoE is always transformer-isolated from the local AC supply.
    – Jamie Hanrahan
    Dec 9 '18 at 21:23






  • 4




    @grawity Ethernet over TP has always used differential signaling. You get it basically free with transformers at each end.
    – Jamie Hanrahan
    Dec 9 '18 at 21:25






  • 4




    @grawity it does. That's basically the reason behind twisted pair; noise will impact each wire almost equally, and thus the difference will be preserved.
    – vidarlo
    Dec 9 '18 at 21:26



















2














If you're at all concerned about it, you can fairly cheaply use a fiber-optic connection instead. That completely avoids the issue by being non-conductive.



Gigabit media converters run for $50–100 a piece, allowing you to fairly cheaply user fiber instead. (Search Amazon or wherever for something like "fiber media converter" and you'll find plenty). This does require running fiber — and that's only easy if you can pull a pre-terminated fiber through existing conduit; that'll add around another $20 for the fiber. If anything is going to fail, it's going to be a media converter (or its power supply); therefor, keep a spare on hand. Total of under $200 including spares easily doable.



Note that there are multiple fiber connectors, so you need to make sure the pre-terminated fiber you buy matches the media converters. At the distance you're running (meters, not kilometers), everything will be multimode fiber and fairly low-power.



[Of course, if you have the tools and know-how to terminate fiber, that makes it easier, you can pull unterminated fiber through a much smaller or more tightly packed conduit. But then I suspect you'd have already considered this option.]






share|improve this answer





















    Your Answer








    StackExchange.ready(function() {
    var channelOptions = {
    tags: "".split(" "),
    id: "3"
    };
    initTagRenderer("".split(" "), "".split(" "), channelOptions);

    StackExchange.using("externalEditor", function() {
    // Have to fire editor after snippets, if snippets enabled
    if (StackExchange.settings.snippets.snippetsEnabled) {
    StackExchange.using("snippets", function() {
    createEditor();
    });
    }
    else {
    createEditor();
    }
    });

    function createEditor() {
    StackExchange.prepareEditor({
    heartbeatType: 'answer',
    autoActivateHeartbeat: false,
    convertImagesToLinks: true,
    noModals: true,
    showLowRepImageUploadWarning: true,
    reputationToPostImages: 10,
    bindNavPrevention: true,
    postfix: "",
    imageUploader: {
    brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
    contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
    allowUrls: true
    },
    onDemand: true,
    discardSelector: ".discard-answer"
    ,immediatelyShowMarkdownHelp:true
    });


    }
    });














    draft saved

    draft discarded


















    StackExchange.ready(
    function () {
    StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fsuperuser.com%2fquestions%2f1382160%2fconnecting-switches-between-two-buildings-each-building-has-it-own-mains-electr%23new-answer', 'question_page');
    }
    );

    Post as a guest















    Required, but never shown

























    2 Answers
    2






    active

    oldest

    votes








    2 Answers
    2






    active

    oldest

    votes









    active

    oldest

    votes






    active

    oldest

    votes









    18














    It won't be a problem. The Ethernet standards for twisted-pair have always required isolation of the signal wires from all local power supplies and grounds. In most equipment using twisted-pair Ethernet this is achieved simply by having all of the pairs run through transformers at each end. There is therefore no metallic connection between the switches or whatever the TP cable is plugged into, and therefore complete isolation, between the equipments' grounds and power supplies.



    If you were using shielded twisted pair, you would want to connect its shield to building frame ground at one and only one end. This was a concern back in the days of 10Base2 and 10Base5 (Ethernet over coax).






    share|improve this answer



















    • 5




      So what about PoE?
      – DavidPostill
      Dec 9 '18 at 21:20






    • 3




      Ethernet uses differential signalling. Thus the interface looks at difference between two wires, not absolute voltage levels. No common zero needs to be identified, as the difference will be equal no matter what gnd is with reference to the other end.
      – vidarlo
      Dec 9 '18 at 21:21






    • 3




      PoE is always transformer-isolated from the local AC supply.
      – Jamie Hanrahan
      Dec 9 '18 at 21:23






    • 4




      @grawity Ethernet over TP has always used differential signaling. You get it basically free with transformers at each end.
      – Jamie Hanrahan
      Dec 9 '18 at 21:25






    • 4




      @grawity it does. That's basically the reason behind twisted pair; noise will impact each wire almost equally, and thus the difference will be preserved.
      – vidarlo
      Dec 9 '18 at 21:26
















    18














    It won't be a problem. The Ethernet standards for twisted-pair have always required isolation of the signal wires from all local power supplies and grounds. In most equipment using twisted-pair Ethernet this is achieved simply by having all of the pairs run through transformers at each end. There is therefore no metallic connection between the switches or whatever the TP cable is plugged into, and therefore complete isolation, between the equipments' grounds and power supplies.



    If you were using shielded twisted pair, you would want to connect its shield to building frame ground at one and only one end. This was a concern back in the days of 10Base2 and 10Base5 (Ethernet over coax).






    share|improve this answer



















    • 5




      So what about PoE?
      – DavidPostill
      Dec 9 '18 at 21:20






    • 3




      Ethernet uses differential signalling. Thus the interface looks at difference between two wires, not absolute voltage levels. No common zero needs to be identified, as the difference will be equal no matter what gnd is with reference to the other end.
      – vidarlo
      Dec 9 '18 at 21:21






    • 3




      PoE is always transformer-isolated from the local AC supply.
      – Jamie Hanrahan
      Dec 9 '18 at 21:23






    • 4




      @grawity Ethernet over TP has always used differential signaling. You get it basically free with transformers at each end.
      – Jamie Hanrahan
      Dec 9 '18 at 21:25






    • 4




      @grawity it does. That's basically the reason behind twisted pair; noise will impact each wire almost equally, and thus the difference will be preserved.
      – vidarlo
      Dec 9 '18 at 21:26














    18












    18








    18






    It won't be a problem. The Ethernet standards for twisted-pair have always required isolation of the signal wires from all local power supplies and grounds. In most equipment using twisted-pair Ethernet this is achieved simply by having all of the pairs run through transformers at each end. There is therefore no metallic connection between the switches or whatever the TP cable is plugged into, and therefore complete isolation, between the equipments' grounds and power supplies.



    If you were using shielded twisted pair, you would want to connect its shield to building frame ground at one and only one end. This was a concern back in the days of 10Base2 and 10Base5 (Ethernet over coax).






    share|improve this answer














    It won't be a problem. The Ethernet standards for twisted-pair have always required isolation of the signal wires from all local power supplies and grounds. In most equipment using twisted-pair Ethernet this is achieved simply by having all of the pairs run through transformers at each end. There is therefore no metallic connection between the switches or whatever the TP cable is plugged into, and therefore complete isolation, between the equipments' grounds and power supplies.



    If you were using shielded twisted pair, you would want to connect its shield to building frame ground at one and only one end. This was a concern back in the days of 10Base2 and 10Base5 (Ethernet over coax).







    share|improve this answer














    share|improve this answer



    share|improve this answer








    edited Dec 10 '18 at 12:39

























    answered Dec 9 '18 at 20:57









    Jamie Hanrahan

    17.8k34078




    17.8k34078








    • 5




      So what about PoE?
      – DavidPostill
      Dec 9 '18 at 21:20






    • 3




      Ethernet uses differential signalling. Thus the interface looks at difference between two wires, not absolute voltage levels. No common zero needs to be identified, as the difference will be equal no matter what gnd is with reference to the other end.
      – vidarlo
      Dec 9 '18 at 21:21






    • 3




      PoE is always transformer-isolated from the local AC supply.
      – Jamie Hanrahan
      Dec 9 '18 at 21:23






    • 4




      @grawity Ethernet over TP has always used differential signaling. You get it basically free with transformers at each end.
      – Jamie Hanrahan
      Dec 9 '18 at 21:25






    • 4




      @grawity it does. That's basically the reason behind twisted pair; noise will impact each wire almost equally, and thus the difference will be preserved.
      – vidarlo
      Dec 9 '18 at 21:26














    • 5




      So what about PoE?
      – DavidPostill
      Dec 9 '18 at 21:20






    • 3




      Ethernet uses differential signalling. Thus the interface looks at difference between two wires, not absolute voltage levels. No common zero needs to be identified, as the difference will be equal no matter what gnd is with reference to the other end.
      – vidarlo
      Dec 9 '18 at 21:21






    • 3




      PoE is always transformer-isolated from the local AC supply.
      – Jamie Hanrahan
      Dec 9 '18 at 21:23






    • 4




      @grawity Ethernet over TP has always used differential signaling. You get it basically free with transformers at each end.
      – Jamie Hanrahan
      Dec 9 '18 at 21:25






    • 4




      @grawity it does. That's basically the reason behind twisted pair; noise will impact each wire almost equally, and thus the difference will be preserved.
      – vidarlo
      Dec 9 '18 at 21:26








    5




    5




    So what about PoE?
    – DavidPostill
    Dec 9 '18 at 21:20




    So what about PoE?
    – DavidPostill
    Dec 9 '18 at 21:20




    3




    3




    Ethernet uses differential signalling. Thus the interface looks at difference between two wires, not absolute voltage levels. No common zero needs to be identified, as the difference will be equal no matter what gnd is with reference to the other end.
    – vidarlo
    Dec 9 '18 at 21:21




    Ethernet uses differential signalling. Thus the interface looks at difference between two wires, not absolute voltage levels. No common zero needs to be identified, as the difference will be equal no matter what gnd is with reference to the other end.
    – vidarlo
    Dec 9 '18 at 21:21




    3




    3




    PoE is always transformer-isolated from the local AC supply.
    – Jamie Hanrahan
    Dec 9 '18 at 21:23




    PoE is always transformer-isolated from the local AC supply.
    – Jamie Hanrahan
    Dec 9 '18 at 21:23




    4




    4




    @grawity Ethernet over TP has always used differential signaling. You get it basically free with transformers at each end.
    – Jamie Hanrahan
    Dec 9 '18 at 21:25




    @grawity Ethernet over TP has always used differential signaling. You get it basically free with transformers at each end.
    – Jamie Hanrahan
    Dec 9 '18 at 21:25




    4




    4




    @grawity it does. That's basically the reason behind twisted pair; noise will impact each wire almost equally, and thus the difference will be preserved.
    – vidarlo
    Dec 9 '18 at 21:26




    @grawity it does. That's basically the reason behind twisted pair; noise will impact each wire almost equally, and thus the difference will be preserved.
    – vidarlo
    Dec 9 '18 at 21:26













    2














    If you're at all concerned about it, you can fairly cheaply use a fiber-optic connection instead. That completely avoids the issue by being non-conductive.



    Gigabit media converters run for $50–100 a piece, allowing you to fairly cheaply user fiber instead. (Search Amazon or wherever for something like "fiber media converter" and you'll find plenty). This does require running fiber — and that's only easy if you can pull a pre-terminated fiber through existing conduit; that'll add around another $20 for the fiber. If anything is going to fail, it's going to be a media converter (or its power supply); therefor, keep a spare on hand. Total of under $200 including spares easily doable.



    Note that there are multiple fiber connectors, so you need to make sure the pre-terminated fiber you buy matches the media converters. At the distance you're running (meters, not kilometers), everything will be multimode fiber and fairly low-power.



    [Of course, if you have the tools and know-how to terminate fiber, that makes it easier, you can pull unterminated fiber through a much smaller or more tightly packed conduit. But then I suspect you'd have already considered this option.]






    share|improve this answer


























      2














      If you're at all concerned about it, you can fairly cheaply use a fiber-optic connection instead. That completely avoids the issue by being non-conductive.



      Gigabit media converters run for $50–100 a piece, allowing you to fairly cheaply user fiber instead. (Search Amazon or wherever for something like "fiber media converter" and you'll find plenty). This does require running fiber — and that's only easy if you can pull a pre-terminated fiber through existing conduit; that'll add around another $20 for the fiber. If anything is going to fail, it's going to be a media converter (or its power supply); therefor, keep a spare on hand. Total of under $200 including spares easily doable.



      Note that there are multiple fiber connectors, so you need to make sure the pre-terminated fiber you buy matches the media converters. At the distance you're running (meters, not kilometers), everything will be multimode fiber and fairly low-power.



      [Of course, if you have the tools and know-how to terminate fiber, that makes it easier, you can pull unterminated fiber through a much smaller or more tightly packed conduit. But then I suspect you'd have already considered this option.]






      share|improve this answer
























        2












        2








        2






        If you're at all concerned about it, you can fairly cheaply use a fiber-optic connection instead. That completely avoids the issue by being non-conductive.



        Gigabit media converters run for $50–100 a piece, allowing you to fairly cheaply user fiber instead. (Search Amazon or wherever for something like "fiber media converter" and you'll find plenty). This does require running fiber — and that's only easy if you can pull a pre-terminated fiber through existing conduit; that'll add around another $20 for the fiber. If anything is going to fail, it's going to be a media converter (or its power supply); therefor, keep a spare on hand. Total of under $200 including spares easily doable.



        Note that there are multiple fiber connectors, so you need to make sure the pre-terminated fiber you buy matches the media converters. At the distance you're running (meters, not kilometers), everything will be multimode fiber and fairly low-power.



        [Of course, if you have the tools and know-how to terminate fiber, that makes it easier, you can pull unterminated fiber through a much smaller or more tightly packed conduit. But then I suspect you'd have already considered this option.]






        share|improve this answer












        If you're at all concerned about it, you can fairly cheaply use a fiber-optic connection instead. That completely avoids the issue by being non-conductive.



        Gigabit media converters run for $50–100 a piece, allowing you to fairly cheaply user fiber instead. (Search Amazon or wherever for something like "fiber media converter" and you'll find plenty). This does require running fiber — and that's only easy if you can pull a pre-terminated fiber through existing conduit; that'll add around another $20 for the fiber. If anything is going to fail, it's going to be a media converter (or its power supply); therefor, keep a spare on hand. Total of under $200 including spares easily doable.



        Note that there are multiple fiber connectors, so you need to make sure the pre-terminated fiber you buy matches the media converters. At the distance you're running (meters, not kilometers), everything will be multimode fiber and fairly low-power.



        [Of course, if you have the tools and know-how to terminate fiber, that makes it easier, you can pull unterminated fiber through a much smaller or more tightly packed conduit. But then I suspect you'd have already considered this option.]







        share|improve this answer












        share|improve this answer



        share|improve this answer










        answered Dec 12 '18 at 19:20









        derobert

        2,9961718




        2,9961718






























            draft saved

            draft discarded




















































            Thanks for contributing an answer to Super User!


            • Please be sure to answer the question. Provide details and share your research!

            But avoid



            • Asking for help, clarification, or responding to other answers.

            • Making statements based on opinion; back them up with references or personal experience.


            To learn more, see our tips on writing great answers.





            Some of your past answers have not been well-received, and you're in danger of being blocked from answering.


            Please pay close attention to the following guidance:


            • Please be sure to answer the question. Provide details and share your research!

            But avoid



            • Asking for help, clarification, or responding to other answers.

            • Making statements based on opinion; back them up with references or personal experience.


            To learn more, see our tips on writing great answers.




            draft saved


            draft discarded














            StackExchange.ready(
            function () {
            StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fsuperuser.com%2fquestions%2f1382160%2fconnecting-switches-between-two-buildings-each-building-has-it-own-mains-electr%23new-answer', 'question_page');
            }
            );

            Post as a guest















            Required, but never shown





















































            Required, but never shown














            Required, but never shown












            Required, but never shown







            Required, but never shown

































            Required, but never shown














            Required, but never shown












            Required, but never shown







            Required, but never shown







            Popular posts from this blog

            Bressuire

            Cabo Verde

            Gyllenstierna